CRT
|
Type |
6-inch rectangular type with internal graticule
8 x 10 div (1div=1cm) |
Accelerating Potential |
2kV |
Z-Axis Input
|
Sensitivity: Above 5Vp-p
Max. input voltage: 30V (DC + AC peak)
Bandwidth: DC ~ 2MHz |
Polarity |
Positive-going input decrease |
Focus Control |
Auto focus |
FUNCTION GENERATOR
|
Frequency Range |
0.1Hz ~ 1MHz (7 range) |
Waveform |
Sine Wave, Square Wave, Triangle Wave |
Frequency Variable Range |
10:1 or more |
Output Impedance |
50Ω±10%
|
Voltage |
Over 14Vpp(open circuit) continuous conversion
DC offset possible over ±6V when open |
Sinewave Distortion |
2% Max. (10Hz ~ 100kHz) |
Squarewave Unsymmetry |
±3% or less (in 1 kHz maximum) |
Squarewave Rise/Fall Time |
50Ω output: 120ns or less |
VERTICAL SYSTEM
|
Sensitivity |
5mV ~ 5V/div ±3%, 1mV ~ 1V/div ±5% (using x5MAG) |
Bandwidth |
DC to 20MHz (x 5MAG: DC to 7MHz) |
Rise Time |
Approx. 17.5ns (x 5MAG: Approx. 50ns) |
Max. Input |
300V (DC+ACpeak) at 1kHz |
Input Coupling |
AC, DC, GND |
Input Impedance |
Approx. 1MΩ // 25pF |
Vertical Mode |
CH1,CH2,DUAL(ALT,CHOP),ADD,CH2 INV |
HORIZONTAL SYSTEM
|
Sweep Time |
0.2μs ~ 0.5s/div ±3% (±5% at x10 MAG)
|
Max. Sweep Rate |
100ns/div (20ns and 50ns/div are uncalibrated) |
TRIGGER
|
Trigger Mode |
AUTO, NORM, TV-V, TV-H |
Trigger Source |
CH1, CH2, ALT, LINE, EXT |
Trigger Slope |
"+" or "-" |
X-Y OPERATION
|
Sensitivity |
5mV ~ 5V/div ±4% |
X-axis Bandwidth |
DC ~ 500kHz |
Phase Error |
3° or less from DC ~ 50kHz |
OUTPUT SIGNAL
|
Ch1 Signal Output |
Voltage: approx. 20mV/div into 50Ω
Bandwidth : 50Hz to 5MHz (-3dB)
Impedance : Approx.50Ω
|
Calibrator Output |
1kHz Square wave, 2Vpp±2% |
POWER SOURCE |
|
AC 115/ 230V ±15%, 50Hz /60Hz |
DIMENSIONS & WEIGHT |
|
310(W) x 150(H) x 455(D)mm; Approx. 8.5kg |